- Главная
- »
- Lab Water Purification Systems
Lab Water Purification Systems
lab water purification systems are specifically designed for analytical testing and laboratory use. These systems use a multi-stage purification process to convert tap water into pure water that meets national laboratory water standards, ensuring reliable results for your experiments.
Features of Our Lab Water Purification Systems
High-Purity Output
The systems produce pure water that meets China's national laboratory water standard GB 6682-2008, Grade I standard. The resistivity of the product water is ≥10 MΩ·cm at 25°C.
Real-time Monitoring
The systems use a precision instrument for online, real-time, and accurate analysis and display of water quality.
Automated Operation
The fully automatic operating system is easy to use and features a unique one-touch operation. The equipment automatically starts and stops water production based on the water volume.
Safety Features
The systems are equipped with low water inlet pressure protection and will automatically stop operation to protect the equipment when there is a water shortage.
Compact and Modular Design
The professional engineering and appearance design make the equipment compact and aesthetically pleasing. A modular design concept makes for easy maintenance and replacement
Advantages of Our Lab Water Purification Systems
Reliable Water Quality: The quality of pure water directly affects test results, as it is a medium or carrier for biological reactions, a diluent or solvent for samples and reagents, and a cleaning fluid for instruments. Our systems ensure the reliability of your results by providing consistently high-quality water.
Easy to Use: The equipment connects directly to a tap water source to produce purified water, making installation easy.
Space-Saving: The compact design minimizes the space required for the equipment.
Technical Parameter
| Product Name | Hospital Laboratory pure water machine |
| Inlet water source | Municipal tap water |
| water yield | 10L/H-2000L/H (customized according to customer requirements) |
| Produced water quality | Electrical resistivity: ≥ 18M Ω· cm (ultrapure water) Heavy metal removal rate: ≥ 99.5% Total bacterial count ≤ 10CFU/mL Total Organic Carbon (TOC):<10pppb |
| application | Biochemical analysis, reagent preparation, parallel water supply for multiple departments (testing+hemodialysis+cleaning) |
| control mode | Fully automatic control (manual control is feasible) |
Model
| Model | Capacity |
| Molresearch 810d | 10L/H |
| Molresearch 820d | 20L/H |
| Molresearch 830d | 30L/H |
| Molresearch 840d | 40L/H |
| Molresearch 850d | 50L/H |
| Larger capacity is available | |
Applications for Lab Water Purification Systems
The pure water produced by our systems is suitable for a wide range of laboratory applications.
Frequently Asked Questions
The pure water produced meets the GB 6682-2008 Grade I national laboratory water standard. The resistivity is ≥10 MΩ·cm at 25°C.
Yes, the system is fully automated. It automatically starts and stops water production, and it has built-in low-pressure and water shortage protection.
The modular design makes maintenance and replacement of parts simple and convenient.
Our systems offer a range of capacities from 10 L/H to 40 L/H, depending on the model.
Yes, our systems are versatile and suitable for a broad range of applications, including general lab analysis, preparing reagents, and for use in microbiology and final instrument rinsing.
You should select a model based on your lab's daily pure water consumption. Our product models are listed by their water production capacity (L/H) to help you choose the right fit.
Related Articles
Membrane BioReactor (MBR): The Engineering Guide to Wastewater Treatment & Reclamation
Introduction: The Evolution of Industrial Wastewater Treatment With shrinking water supplies and tightening discharge limits, the industrial sector is facing a massive shift. We can no longer treat wastewater as a waste product; it has become a critical resource for reclamation. This urgency is what has pushed Membrane Bioreactor (MBR) technology to the forefront of […]
PW vs. WFI
Water for Injection (WFI): The Gold Standard for Safety The Rigor of Purity Water for Injection is essentially the ultra-pure evolution of PW. It is required for any medication that is administered parenterally (bypassing the digestive system) or used for the final rinsing of sterile components. The Feature:Traditionally, Water for Injection was produced exclusively via Multi-Effect […]
RO vs EDI Solution in Pharma
The Technical Foundation: How RO and EDI Solution Work To select the right system, one must understand the synergy between these two technologies. Reverse Osmosis (RO) serves as the essential primary purification stage. By using high-pressure pumps to force water through semi-permeable membranes, it effectively rejects up to 99% of dissolved salts, organics, and bacteria. It is […]
Get in touch with us
Don’t let water quality issues stand in your way. MoerWater Purified Water Generator will help you solve all your water quality problems, improve operational efficiency, and ensure your product or experimental results are at the best level.
*Our team will answer your inquiries within 24 hours.